Test an unknown output transformer with a low AC voltage and compare its measured turns ratio with common guitar-amplifier impedances.
Measured result
Reference combinations
Expected secondary AC voltages with 15 V applied to the primary| Target primary | Speaker | Turns ratio | Expected V | V range (±Z tolerance) | Actual Z difference |
|---|
Green = nearest listed combination within tolerance. Pale yellow = other combinations within tolerance. Matching a nominal value does not identify the transformer's intended rating.
How the calculation works
The voltage ratio approximates the turns ratio when the secondary is unloaded:
The impedance seen by the output valves depends on which speaker is connected:
For reference combinations, the calculator works backwards to find the expected secondary voltage. The tolerance is applied to primary impedance, so the displayed voltage limits are not symmetrical around the nominal voltage.
Source: Merlin Blencowe, Valve Amplifiers, 4th ed., Chapter 1, p. 25. Measurements establish a turns ratio, not the transformer's power rating, insulation condition, frequency response or suitability for single-ended use.