Output Transformer Primary Inductance

Output Transformer Primary Inductance Calculator

Estimate the open-circuit primary inductance of an output transformer from a low-voltage sine-wave test. The calculator distinguishes impedance magnitude from inductive reactance and can use an optional third voltage reading for a better estimate.

Test connections

AC signal generator sine wave Series R OT primary Measure V_R Measure V_T Secondary OPEN Optional: measure V_total across resistor + primary
  1. Test the disconnected, unpowered transformer. Leave all secondary windings open: no speaker or dummy load.
  2. For push-pull output transformers, test between the two plate leads (full primary); leave the centre tap unconnected. For single-ended transformers, test the complete primary.
  3. Connect a known series resistor between the signal generator and primary, as shown. Use a low-voltage sine wave (80 Hz is close to a guitar's low E at 82.4 Hz).
  4. Measure the AC RMS voltage across the series resistor (V_R) and primary winding (V_T). Use readings taken at the same frequency and test level.
  5. For better accuracy, enter the primary's DC resistance, or expand the optional three-voltage method below.

Measurements

Improve accuracy: optional three-voltage method

Measure the total AC RMS voltage across the series resistor and primary together, not just the generator's display setting. Three voltage readings allow the equivalent AC resistance and inductive reactance to be separated by phasor geometry. Assumes the transformer is inductive at the test frequency.

Enter both measured AC voltages to calculate.

What this test does - and doesn't - tell you

With only the two component voltages, V_T / V_R gives the magnitude of impedance, not inductive reactance by itself. A DCR correction improves the estimate if copper resistance dominates the AC losses. The optional third voltage is better because it estimates the impedance phase, including resistive core losses.

Transformer magnetising inductance changes with applied voltage, frequency and magnetic state. This low-voltage, open-secondary test is a useful comparison between transformers, not a prediction of amplifier bass response or its -3 dB cutoff. In a single-ended transformer, DC plate current changes the operating permeability; this test does not reproduce that bias condition.

Safety: Disconnect the transformer from the amplifier and discharge all capacitors before testing. Never connect a signal generator to a live valve-amplifier output stage.